← All Components Wire in Designer
Victron Energy Chargers & Inverters DC-DC Battery Charger

Orion XS 12/12-50

Next-gen non-isolated DC-DC charger. 50A output. Shared GND terminal (common negative for IN and OUT). Includes VE.Direct port and Remote on/off terminal.

Voltage 12.0 V DC
Current 50 A
Efficiency 98.5%

Technical & Electrical Specifications

Input Voltage Range
14
Rated Output Current
50 A
Operating Efficiency
98.5%

Terminal Pinouts & Hardware Connections

Verify physical terminal sizes, stud threads (M6, M8, M10), and circuit polarity before crimping lugs or running wiring.

Hardware terminal connection details and stud sizes for Orion XS 12/12-50
Terminal Label Polarity / Type Nominal Voltage Physical Hardware Location
IN
in_pos
+ DC Positive 12.0V Standard Terminal Top Panel
GND
gnd
- DC Negative 12.0V Standard Terminal Top Panel
OUT
out_pos
+ DC Positive 12.0V Standard Terminal Bottom Panel
REM
remote
Control 12.0V Standard Terminal Bottom Panel
VED
ve_direct
Data 12.0V Standard Terminal Bottom Panel
Installation Safety Standard: Always size circuit protection (ANL, MIDI, or MEGA fuses) to protect the cable run attached to these terminals against dead shorts and thermal overload, in compliance with AS/NZS 3001, AS/NZS 3004, and ABYC E-11 standards.

Official Product Manual & Wiring Guidelines

Manufacturer technical instructions, safety precautions, and troubleshooting procedures.

1. Safety Instructions

WARNING: REVERSE POLARITY
Incorrect polarity will permanently damage the unit. Verify: IN to source battery positive, GND to common negative, OUT to service battery positive.
WARNING: FUSE BOTH CABLES
Install a 60–70A MEGA fuse on the IN cable and a 60A fuse on the OUT cable, each as close as possible to the respective battery.
CAUTION: NON-ISOLATED UNIT
The Orion XS 12/12-50 is non-isolated. The GND terminal is the single common negative shared between input and output. Do not install separate IN- and OUT- connections — they are internally joined.