← Components Wire
Victron Energy System Monitors & Shunts System Controller / Gateway

Cerbo GX MK2 System Monitor

Next-generation communication hub (MK2). Links all Victron devices — MPPT, inverter/chargers, batteries, shunts — via VE.Direct, VE.Bus, and VE.Can. Features 2x fully configurable VE.Can ports (1 isolated), 3x full USB host ports, 3x VE.Direct ports, 2x VE.Bus RJ45, Wi-Fi, Bluetooth, and Ethernet. Venus OS powered.

Voltage 12 V DC
Current 0.4 A

Technical & Electrical Specifications

Nominal Voltage
12 V DC
Continuous Current Draw
0.4 A
Default Duty Cycle
1
Estimated Daily Use
24
Critical
False

Terminal Pinouts & Hardware Connections

Verify physical terminal sizes, stud threads (M6, M8, M10), and circuit polarity before crimping lugs or running wiring.

Hardware terminal connection details and stud sizes for Cerbo GX MK2 System Monitor
Terminal Label Polarity / Type Nominal Voltage Physical Hardware Location
V+
power_pos
+ DC Positive 12V Screw Terminal Clamp Top Panel
V-
power_neg
- DC Negative 12V Screw Terminal Clamp Top Panel
VED1
ved1
Data 12V Screw Terminal Clamp Bottom Panel
VED2
ved2
Data 12V Screw Terminal Clamp Bottom Panel
VED3
ved3
Data 12V Screw Terminal Clamp Bottom Panel
VEB1
vebus
Data 12V Screw Terminal Clamp Bottom Panel
VEB2
vebus2
Data 12V Standard Terminal Bottom Panel
CAN
vecan
Data 12V Screw Terminal Clamp Bottom Panel
BMS
bmscan
Data 12V Standard Terminal Bottom Panel
GX
gx_touch
Data 12V Screw Terminal Clamp Right Panel
Installation Safety Standard: Always size circuit protection (ANL, MIDI, or MEGA fuses) to protect the cable run attached to these terminals against dead shorts and thermal overload, in compliance with AS/NZS 3001, AS/NZS 3004, and ABYC E-11 standards.

Official Product Manual & Wiring Guidelines

Manufacturer technical instructions, safety precautions, and troubleshooting procedures.

1. Safety Instructions

WARNING: POWER THE CERBO FROM THE BATTERY
Always power the Cerbo GX MK2 directly from the system battery, never from the AC-out of an inverter/charger. If the inverter shuts down due to a fault, a Cerbo powered from AC-out will also lose power, preventing it from recovering the system — a deadlock.
WARNING: INLINE FUSE REQUIRED
The supplied DC cable includes an inline 3.15A slow-blow fuse. Always ensure this fuse is intact. Do not bypass it or use a higher-rated fuse.
CAUTION: VE.Can TERMINATION
Both ends of every VE.Can network must be terminated with the supplied blue RJ45 terminators. An un-terminated bus will cause communication errors across all connected devices.
Note: The Cerbo GX MK2 is rated IP20 — indoor use only. Do not expose to rain, condensation, or direct water contact.

Plan Your System with the Cerbo GX MK2 System Monitor

Add this Victron Energy component straight into our interactive canvas designer. Connect virtual cables, verify fuse ratings, run live appliance simulations, and ensure full standards compliance before you touch a drill or cut a cable.

Open in Visual Designer — Free & Instant