← All Components Wire in Designer
Victron Energy Chargers & Inverters Inverter Charger

MultiPlus-II 24/3000/70-32

24V 3000VA (2400W continuous) pure sine wave inverter with integrated 70A 24V battery charger and 32A automatic AC transfer switch.

Voltage 24 V DC
Current 70 A
Power 3000 VA

Technical & Electrical Specifications

Nominal Voltage
24 V DC
Continuous Inverter Rating
3000 VA
Charging Output Current
70 A
AC Output Load
0 W
Shore Power Limit
32 A

Terminal Pinouts & Hardware Connections

Verify physical terminal sizes, stud threads (M6, M8, M10), and circuit polarity before crimping lugs or running wiring.

Hardware terminal connection details and stud sizes for MultiPlus-II 24/3000/70-32
Terminal Label Polarity / Type Nominal Voltage Physical Hardware Location
DC+
dc_pos
+ DC Positive 24V Standard Terminal Bottom Panel
DC-
dc_neg
- DC Negative 24V Standard Terminal Bottom Panel
AC IN
ac_in
~ AC Terminal 24V Standard Terminal Left Panel
AC OUT
ac_out
~ AC Terminal 24V Standard Terminal Right Panel
AC GND
ac_gnd
⏚ Chassis Ground 24V Standard Terminal Right Panel
VEB
ve_bus
Data 24V Standard Terminal Bottom Panel
Installation Safety Standard: Always size circuit protection (ANL, MIDI, or MEGA fuses) to protect the cable run attached to these terminals against dead shorts and thermal overload, in compliance with AS/NZS 3001, AS/NZS 3004, and ABYC E-11 standards.

Official Product Manual & Wiring Guidelines

Manufacturer technical instructions, safety precautions, and troubleshooting procedures.

Download PDF Manual

1. Safety Instructions

HIGH VOLTAGE / SHOCK HAZARD: 230V AC output can be present even when DC is isolated (PowerAssist / Inverter). Always isolate AC and DC supplies before servicing.
  • Connect DC cables to a 24V nominal battery bank only. Minimum cable: 35–50 mm².
  • DC Fuse: 200A MEGA or Class-T fuse in the positive line within 1m of battery bank.