Lynx Distributor (1000A)

Highly robust positive and negative busbar. Houses 4 MEGA fuse connections with LED monitoring.

Voltage 12.0 V DC
Current 1000 A

Technical & Electrical Specifications

Max Current Rating
1000 A

Terminal Pinouts & Hardware Connections

Verify physical terminal sizes, stud threads (M6, M8, M10), and circuit polarity before crimping lugs or running wiring.

Hardware terminal connection details and stud sizes for Lynx Distributor (1000A)
Terminal Label Polarity / Type Nominal Voltage Physical Hardware Location
POS IN
main_pos_in
+ DC Positive 12.0V Standard Terminal Left Panel
NEG IN
main_neg_in
- DC Negative 12.0V Standard Terminal Left Panel
POS OUT
main_pos_out
+ DC Positive 12.0V Standard Terminal Right Panel
NEG OUT
main_neg_out
- DC Negative 12.0V Standard Terminal Right Panel
F1+
fuse1_pos
+ DC Positive 12.0V Standard Terminal Bottom Panel
F1-
fuse1_neg
- DC Negative 12.0V Standard Terminal Bottom Panel
F2+
fuse2_pos
+ DC Positive 12.0V Standard Terminal Bottom Panel
F2-
fuse2_neg
- DC Negative 12.0V Standard Terminal Bottom Panel
F3+
fuse3_pos
+ DC Positive 12.0V Standard Terminal Bottom Panel
F3-
fuse3_neg
- DC Negative 12.0V Standard Terminal Bottom Panel
F4+
fuse4_pos
+ DC Positive 12.0V Standard Terminal Bottom Panel
F4-
fuse4_neg
- DC Negative 12.0V Standard Terminal Bottom Panel
GND
chassis_gnd
⏚ Chassis Ground 12.0V Standard Terminal Top Panel
Installation Safety Standard: Always size circuit protection (ANL, MIDI, or MEGA fuses) to protect the cable run attached to these terminals against dead shorts and thermal overload, in compliance with AS/NZS 3001, AS/NZS 3004, and ABYC E-11 standards.

Official Product Manual & Wiring Guidelines

Manufacturer technical instructions, safety precautions, and troubleshooting procedures.

1. Safety Instructions

WARNING: LIVE BUSBARS SHOCK HAZARD
Do not work on live busbars. Ensure that the busbar is unpowered by disconnecting all positive battery poles prior to removing the Lynx front cover.
QUALIFIED PERSONNEL ONLY
Work on batteries and DC systems should be carried out by qualified personnel only. Observe the battery safety warnings as listed in the battery manual.

Transport and Storage

  • Store this product in a dry environment.
  • The storage temperature should be: -40°C to +65°C.