← All Components Wire in Designer
MaxxECU Distribution & Protection Power Distribution Module (PDM)

MaxxECU PDM20

20-channel fully programmable PDM. 8×25A + 8×15A + 4×8A outputs, 230A total. All 20 channels are PWM-capable. Soft-start, auto-reset, adjustable current limits. CAN bus integration with MaxxECU Race/Pro.

Voltage 12.0 V DC

Technical & Electrical Specifications

Total PDM Rating
230 A
Max Current per Channel
25 A
Switched Channels
20 Outputs

Terminal Pinouts & Hardware Connections

Verify physical terminal sizes, stud threads (M6, M8, M10), and circuit polarity before crimping lugs or running wiring.

Hardware terminal connection details and stud sizes for MaxxECU PDM20
Terminal Label Polarity / Type Nominal Voltage Physical Hardware Location
BAT+
main_pos
+ DC Positive 12.0V Standard Terminal Left Panel
BAT-
main_neg
- DC Negative 12.0V Standard Terminal Left Panel
CH1
ch1
+ DC Positive 12.0V Standard Terminal Right Panel
CH2
ch2
+ DC Positive 12.0V Standard Terminal Right Panel
CH3
ch3
+ DC Positive 12.0V Standard Terminal Right Panel
CH4
ch4
+ DC Positive 12.0V Standard Terminal Right Panel
CH5
ch5
+ DC Positive 12.0V Standard Terminal Right Panel
CH6
ch6
+ DC Positive 12.0V Standard Terminal Right Panel
CH7
ch7
+ DC Positive 12.0V Standard Terminal Right Panel
CH8
ch8
+ DC Positive 12.0V Standard Terminal Right Panel
CH9
ch9
+ DC Positive 12.0V Standard Terminal Right Panel
CH10
ch10
+ DC Positive 12.0V Standard Terminal Right Panel
CH11
ch11
+ DC Positive 12.0V Standard Terminal Right Panel
CH12
ch12
+ DC Positive 12.0V Standard Terminal Right Panel
CH13
ch13
+ DC Positive 12.0V Standard Terminal Right Panel
CH14
ch14
+ DC Positive 12.0V Standard Terminal Right Panel
CH15
ch15
+ DC Positive 12.0V Standard Terminal Right Panel
CH16
ch16
+ DC Positive 12.0V Standard Terminal Right Panel
CH17
ch17
+ DC Positive 12.0V Standard Terminal Right Panel
CH18
ch18
+ DC Positive 12.0V Standard Terminal Right Panel
CH19
ch19
+ DC Positive 12.0V Standard Terminal Right Panel
CH20
ch20
+ DC Positive 12.0V Standard Terminal Right Panel
GND
gnd_bus
- DC Negative 12.0V Standard Terminal Bottom Panel
Installation Safety Standard: Always size circuit protection (ANL, MIDI, or MEGA fuses) to protect the cable run attached to these terminals against dead shorts and thermal overload, in compliance with AS/NZS 3001, AS/NZS 3004, and ABYC E-11 standards.