← All Components Wire in Designer
Cartek Motorsport Distribution & Protection Power Distribution Module (PDM)

Cartek PDP-16

16-channel integrated PDM + switch panel. Selectable 5/10/15A per channel (combine for 20/25/30A). 160A total. Solid-state, sealed, no moving parts. Push-button config, no laptop needed. CAN bus, soft-start, RGB status LEDs.

Voltage 12.0 V DC

Technical & Electrical Specifications

Total PDM Rating
160 A
Max Current per Channel
15 A
Switched Channels
16 Outputs

Terminal Pinouts & Hardware Connections

Verify physical terminal sizes, stud threads (M6, M8, M10), and circuit polarity before crimping lugs or running wiring.

Hardware terminal connection details and stud sizes for Cartek PDP-16
Terminal Label Polarity / Type Nominal Voltage Physical Hardware Location
BAT+
main_pos
+ DC Positive 12.0V Standard Terminal Left Panel
BAT-
main_neg
- DC Negative 12.0V Standard Terminal Left Panel
CH1
ch1
+ DC Positive 12.0V Standard Terminal Right Panel
CH2
ch2
+ DC Positive 12.0V Standard Terminal Right Panel
CH3
ch3
+ DC Positive 12.0V Standard Terminal Right Panel
CH4
ch4
+ DC Positive 12.0V Standard Terminal Right Panel
CH5
ch5
+ DC Positive 12.0V Standard Terminal Right Panel
CH6
ch6
+ DC Positive 12.0V Standard Terminal Right Panel
CH7
ch7
+ DC Positive 12.0V Standard Terminal Right Panel
CH8
ch8
+ DC Positive 12.0V Standard Terminal Right Panel
CH9
ch9
+ DC Positive 12.0V Standard Terminal Right Panel
CH10
ch10
+ DC Positive 12.0V Standard Terminal Right Panel
CH11
ch11
+ DC Positive 12.0V Standard Terminal Right Panel
CH12
ch12
+ DC Positive 12.0V Standard Terminal Right Panel
CH13
ch13
+ DC Positive 12.0V Standard Terminal Right Panel
CH14
ch14
+ DC Positive 12.0V Standard Terminal Right Panel
CH15
ch15
+ DC Positive 12.0V Standard Terminal Right Panel
CH16
ch16
+ DC Positive 12.0V Standard Terminal Right Panel
GND
gnd_bus
- DC Negative 12.0V Standard Terminal Bottom Panel
Installation Safety Standard: Always size circuit protection (ANL, MIDI, or MEGA fuses) to protect the cable run attached to these terminals against dead shorts and thermal overload, in compliance with AS/NZS 3001, AS/NZS 3004, and ABYC E-11 standards.

Plan Your System with the Cartek PDP-16

Add this Cartek Motorsport component straight into our interactive canvas designer. Connect virtual cables, verify fuse ratings, run live appliance simulations, and ensure full standards compliance before you touch a drill or cut a cable.

Open in Visual Designer — Free & Instant
Advertisement